Building a Simple Sifter takes a Raspberry Pi 4 or 5 (the 5 gives the best performance), a USB-C power supply, an SD card, and a Fujitsu or Ricoh document scanner. The fi-8170 is the model the Sifter is tuned for. SortSwift does not sell any of the parts and the Sifter image is free.
You can run up to four scanners from one Pi, one on the free plan and up to four on a paid scanning plan. The image updates itself after that. It installs a new version whenever it starts, and from Simple Sifter 11.6.1 it also installs one by itself once no scanner is running and nothing has been scanned for 30 minutes, then restarts once. An update never starts while you are scanning, and from 11.6.35 not while you are reviewing cards either: approving, editing, deleting or sending a card restarts the 30 minutes. There is no reconfiguration after an update or a restart, and every setting is saved per scanner.
Older Sifters: every Sifter update now comes out for the 64-bit image only. A Sifter flashed with the earlier 32-bit image (its page shows a version lower than 11.5.2) keeps working, but it gets no more updates until it is reflashed with the 64-bit image. Flashing erases the SD card and everything the Sifter keeps on it: each scanner's settings (Quality, crop settings and stop rules), the active batch and every saved batch, the label settings and templates, and the store logo. The Pi and the scanner stay as they are. Before you flash, finish and send any batch you still need. To keep your saved batches, click Export All under Saved Batches on the Sifter's page and keep the file it downloads. Scanner settings cannot be exported, so note down any you want to set up the same way. Then flash the SD card with the 64-bit image as above, plug in the Ethernet cable or join the simplesifter Wi-Fi again, clear the certificate warning again and log in. To bring the saved batches back, click Import under Saved Batches and pick the file you downloaded.
Do not open, mount or double click the image in Windows. If you do, Windows shows "Couldn't Mount File. The disc image file is corrupted." That does not mean the download is damaged. File Explorer can only open ISO style disc images, and the Sifter file is a Raspberry Pi SD card layout, so Windows cannot read it even when every byte is intact. Close the message and flash the file with Balena Etcher instead. Etcher takes either the downloaded .img.gz or an already extracted .img, so there is no need to download it again. The download is about 2.0 GB and extracts to about 7.3 GB.
If you flash with Raspberry Pi Imager instead of Etcher, use Choose OS then Use custom, and when Imager offers OS customisation choose No. Customising replaces the user the Sifter's own start-up steps run as, and the Sifter does not start properly.
Do not install PaperStream on the Pi. The Pi drives the scanner through SANE, the Linux driver stack, and the image already has everything it needs. PaperStream is only for the separate route where the scanner is plugged into a Windows laptop.
Two computer settings are also needed to reach the Sifter. Your computer's network must be set to Private, not Public: on Windows open Settings, then Network and internet, click the WiFi or Ethernet connection you are on, and set Network profile type to Private network. Your browser must also be allowed to access local devices: when Chrome asks, choose Allow, or click the icon to the left of the address bar on the SortSwift scanner page, open Site settings, and set Local network access to Allow.
Was this article helpful?
Rollover Scans
Scan Result Review
Scan Credits
Upload Issues
Improving Image Quality